Products

Usage examples
Module MR-17H1P2

Module MR-17H1P2

Product designation

Module MR-17H1P2 is designed to be installed on the universal multiservice SG-17R platform as SHDSL channel-forming equipment Module MR-17H1P2 provides remote power to regenerators, modems and IP-cameras over information line

Sections:


Technical characteristics

  • G.SHDSL linear  interface parameters
    • Number of interfaces: %%количество портов на модуле%%
    • Interface type: G.SHDSL (ITU-T G.991.2.bis recommended) 
    • Link type: point-to-point
    • Number of wires per line: 2 (one pair) 
    • Transfer rate, kbit/sec: 64 – 14080
    • Linear code: ТС-РАМ 192
    • Connection type: FDx 
    • Compatibility: SG-17, SG-17+
  • System Interface parameters
    • Electric butting type: PCI 
    • Bus-Master mode: available 
    • Maximum number of modules installed on SG-17R-1RU-CP1-4ETH  base platform: 3
    • Maximum number of modules installed on SG- SG-17R-1RU-CP2-3SFP base platform: 4
  • Other characteristics
    • Module size (with the lath):
      • height, mm: 20
      • width, mm: 164
      • depth, mm: 125
    • Weight, g:
    • Power consumption, W: %%потребление%%
  • Service conditions
    • installed on the SG-17R base platform
    • Air temperature: 10 – 40°С
    • Relative humidity:  up to 85% 
    • Air pressure: 84 – 107 kPa
 

 

  • Remote power supply
    • Remote power supply: available
    • Remote power supply value, V: 240
    • Reboot indicator: available
    • Reboot at, mA: 70
    • Offset indicator: available
    • Offset at, V: 30
    • Max power consumption for regenerators with remote power supply: 20 W for one channel 
  • Service traffic
    • ST mode support: available 
Rate table
Rate, kbit/s0.5 mm cable, km0.9 mm cable, km (*)1.2 mm cable, km (*)
140801,03,65,8
128001,23,86,4
115201,44,26,4
102402,04,67,2
92162,24,87,4
81922,45,08,0
71683,05,48,4
61443,46,09,0
56963,66,810,6
51203,87,212,0
46084,07,413,0
40964,48,014,0
30725,09,015,8
23045,410,617,0
20486,212,619,4
15367,014,822,2
10247,817,026,0
7688,418,428,0
5129,019,830,0
3849,621,232,0
19210,423,035,0
 
(*) - not all data obtained expermentally.

Usage examples

Uniting Ethernet networks over several pairs using different interfaces: SHDSL, E1, RS232

Объединение Ethernet сетей по нескольким парам с использованием различных интерфейсов: SHDSL, E1, RS232

Usage example description

Purpose: uniting two Ethernet networks to reach full output in the link by using the bonding mode. In this scheme SG-17R provides either internetwork connection between two Ethernet groups with routing rules or bridge link with shared addressing of the networks united. Transfer rate over each pair reaches 14080 kbit/s. Different transfer rate may be set up in different pairs. It is important that even if on one of the pairs there is a link loss, the performance of the channel does not fail. Up to 6 pairs may be simultaneously linked to a single SG-17R device for SHDSL links based on SG-17R-1RU-CP1-4ETH platform. Up to 8 pairs may be simultaneously linked to a single SG-17R device for SHDSL links based on SG-17R-1RU-CP2-3SFP platform. Besides, in the bonding mode it is possible to unite any kind of channel-forming equipment, through which IP-traffic is transferred: E1, RS-232. Both Ether-HDLC and PPP-multilink may be chosen as protocols.  

Using in usage example products and product groups
( SG-17R-1RU-CP1-4ETH/220VAC-W1 base platform, SG-17R-1RU-CP1-4ETH/DC base platform, SG-17R-1RU-CP2-3SFP/220VAC-W1 base platform ), ( Module MR-17G1, Module MR-17G2, Module MR-17G4, Module MR-17G8 ), ( Module MR-17H1, Module MR-17H1P2, Module MR-17H2, Module MR-17H2P2 ), ( Module MR-17S2C, Module MR-17S2T, Module MR-17S4C, Module MR-17S4T )


Uniting Ethernet networks using SHDSL with VLAN-assisted traffic isolation

Объединение Ethernet сетей с использованием SHDSL технологии с изоляцией трафика при помощи VLAN

Usage example description

Purpose: splitting the users’ traffic in the shared physical medium of data transfer. The SG-17R device supporting VLAN technology allows uniting LAN 1 and LAN 2 networks independently. Up to 4 Ethernet networks may be simultaneously linked to a single SG-17R. Each Ethernet port may be set up so as to transfer either the whole traffic or single packets with a certain VLAN number. Transfer rate over each pair reaches 14080 kbit/s. Up to 6 pairs may be simultaneously linked to a single device based on SG-17R-1RU-CP1-4ETH platform. Up to 8 pairs may be simultaneously linked to a single device based on SG-17R-1RU-CP2-3SFP platform.

 
Using in usage example products and product groups
( SG-17R-1RU-CP1-4ETH/220VAC-W1 base platform, SG-17R-1RU-CP1-4ETH/DC base platform, SG-17R-1RU-CP2-3SFP/220VAC-W1 base platform ), ( Module MR-17H1, Module MR-17H1P2, Module MR-17H2, Module MR-17H2P2 )


Uniting Ethernet networks using SHDSL with remote power supply

Объединение Ethernet сетей с использованием SHDSL технологии с подачей дистанционного питания

Usage example description

Purpose: linking remote points (single computers or local Ethernet networks) over bridge link with shared addressing mode. Transfer rate over single pair reaches 15296 kbit/s. SG-17B allows translating VLAN IEEE 802.1Q tags either over SHDSL or over Ethernet interfaces. The SG-17BP modem receives remote power from the line from SHDSL modules, installed on SG-17R or SG-17AM DSLAM. 

Using in usage example products and product groups
SHDSL модем SG-17B-P-M, SG-17BP SHDSL modem, Module MR-17H1P2, Module MR-17H2P2, ( SG-17R-1RU-CP1-4ETH/220VAC-W1 base platform, SG-17R-1RU-CP1-4ETH/DC base platform, SG-17R-1RU-CP2-3SFP/220VAC-W1 base platform )


View all usage examples



Supported products

The product can be used with the following products:


Certificates

The Module MR-17H1P2 holds the “Declaration of conformity” issued by the Federal Communications Agency of the Russian Federation on November 8, 2008, №DTS-2561.

 


Price and warranty

Warranty
5 years

Price
Product name Quantity (pc.) Price in USD Price in FOB USD:
Total order